All

varelen factory products

Products 

 

 

Email: hunhr@varelen.com

Wechat:008617307414252

 

 

 

Your present location:index >> Products & service >> Special transformer >> Shift-phase rectifier transformer
  • Product: Shift-phase rectifier transformer
  • Rated capacity: 100-6000kVA
  • Frequency: 50-60Hz
  • Primary voltage: 3,6,10kV
  • Secondary voltage: 6,9,12,15,18,21,24,27kV

WHY VERELEN

1. One of the drafters of the National Standard Mine Flameproof Mobile Substations (GB/T 8286-xxxx ), which will replace the existing national standard (GB/T 8286-2005 ) and it was submitted for trial in Beijing.

2. +20 years experience R&D team, derived from 60 years of history transformer manufacturer in Changsha, Hunan, China since 1956.

3. Full range of transformer types with customized functions is available.

4. CE & ISO certificated.

 

Tests

Below are the tests conducted by Varelen before delivery. Other tests required by clients can also be done accordingly.

Insulation resistance

Resistance of all windings

Check voltage ratio and vector group

No-load test at rated frequency and rated voltage

Impedance test

Withstand voltage test

Induced over-voltage withstand test

Partial discharge measurement

 

Purpose
Providing the multiphase rectifier power to middle and high voltage inverter, playing a multiple role of isolation and phase shifting, mainly used in boiler fan in power plant, water supply system and metallurgy, chemical industry and municipal engineering of automated control system.


Characteristics


Excellent structure, small size and high reliability:
1. With electromagnetic and structural optimization design, small size and lower noise;
2. Same mold windings, special support structure for coil end surface, high strength mechanical, high ability of withstand short-circuit, safe and reliable;
3. Maintenance-free fastening body structure, keep reliable in the long-distance transport and operation
4.Lead lays out neatly, reasonable and nice.


High-quality material and good performance:
1. Made of Class C Dupont insulation materials with big running temperature rise margin, strong overload capacity, high fire resistance, good thermal stability and long service life.
2. Adopted vacuum pressure impregnation Class C  with UL insulating paint to ensure moisture proof, dust-proof, anti-contamination and low partial discharge.
3. With high-quality core made of silicon steel sheet and high-quality oxygen-free copper wire to reduce the effective operation loss and improve efficiency.


Good solution to harmonic influence:
1. Made of high-performance silicon steel sheet material and lower magnetic flux density design so as to withstand overvoltage and harmonic influence unsaturated.     
2. Lower current density design and sufficient margin to make winding withstand additional temperature rise caused by harmonic.
3. Advanced insulation structure that can withstand a variety of over-load insulation impact.
4. Reaching up to maximum 27 phase for secondary winding in result a great reduction of the harmonics influence on the power grid and other equipment.

multi-winding dry-type transformer
Main technical parameters
 

Type Dry type
Phase three phase
Frequency 50/60HZ
Cooling mode AN AF
Capacity 250 to 10000kva
Rated HV 3KV to 13.8KV
Rated LV 3KV to 10kv
Temperature rise 125K
Insulation Class H
Winding connection Code Y/E/yn
Secondary Winding Available 6,9,12,15,18,21,24,27,36 windings